Specification of BALTUR BTG 3.6 P/BTG3.6P/BTG 6 P L300/BTG 11 P/BTG 11 P L300/BTG 15 P/BTG 20 P/BTG 28 P

BALTUR Series BTG P

Two-stage gas burners.

Two-stage.


Series BTG P
Two-stage gas burners.
Two-stage.

BTG 3,6 P 50-60Hz 16.3-41.9kW
BTG3,6P 50-60Hz 16.3-41.9Kw
BTG 6 P L300 50-60Hz 30.6-56.3kW
BTG 11 P 50-60Hz 48.8-99kW
BTG 11 P L300 50-60Hz 48.8-99kW
BTG 15 P 50-60Hz 50-160kW
BTG 20 P 50-60Hz 60-205kW
BTG 28 P 50Hz 80-280kW
BTG 28 P 60Hz 80-280kW
Technical Descriptions
Gas burner compliant with European standard EN676. Two-stage operation.
Gas burner with low NOx and CO emissions in accordance with European standard EN676: class 2.
Regulating combustion air and blast-pipe.
Combustion air intake with throttle damper. Air flow adjustment with electric servomotor.
Fully closing air damper on shutdown to avoid loss of heat through the chimney.
Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
Sliding boiler coupling flange to adapt the blast-pipe to the various types of boilers.
CE version gas train is complete with operation and safety valve with electromagnetic drive, minimum pressure switch, pressure regulator and gas filter.
Possibility to choose gas train with valve tightness control.
Fail proof connectors for burner/gas train connection
Gas train exit: high.
Sound-proof plastic protective cover.
Flame detection by ionisation electrode with connector for micro amp meter.
7-pole socket for burner electric and thermostatic supply.
4-pole socket for second stage control.
Electric protection rating:

Gas burner compliant with European standard EN676. Two­stage operation.
Gas burner with low NOx and CO emissions in accordance with European standard EN676: class 2.
Regulating combustion air and blast­pipe.
Combustion air intake with throttle damper. Air flow adjustment with electric servomotor.
Fully closing air damper on shutdown to avoid loss of heat through the chimney.
Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
Sliding boiler coupling flange to adapt the blast­pipe to the various types of boilers.
CE version gas train is complete with operation and safety valve with electromagnetic drive, minimum pressure switch, pressure
regulator and gas filter.
Possibility to choose gas train with valve tightness control.
Fail proof connectors for burner/gas train connection
Gas train exit: high.
Sound­proof plastic protective cover.
Flame detection by ionisation electrode with connector for micro amp meter.
7­pole socket for burner electric and thermostatic supply.
4­pole socket for second stage control.
Electric protection rating:

Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

17155410.pdf

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Request a Quote
Produk Siap di Pesan
Rp 0
1